The Epoch 48V 100Ah V2-T Elite LiFePO4 battery stores 5.12 kWh of deep-cycle energy in a single IP67-rated case. It is designed for 48V off-grid solar, marine house power, RV and backup systems. A user-serviceable 250A Class T fuse, native Victron CAN communication, internal heating and Bluetooth monitoring through the included battery gauge are all built in. Explore more options in our lithium marine battery collection.
The 250A Class T fuse improves source protection at the battery, and if it opens, it can be replaced through the sealed service panel without opening the case. The smart BMS protects against overcharge, over-discharge, over-current, short circuit and high or low temperature. The cells are listed to UL 1642, UL 9540A and IEC 62619:2022, and the internal fuse to UL 60691. The built-in fuse does not replace system protection: a DC-rated main fuse or breaker close to the positive terminal, a disconnect and correct cable sizing are still required.
Connected to a compatible Victron GX device, the battery provides BMS data for DVCC, state-of-charge reporting, alarms and coordinated charging control. Batteries in a bank are daisy-chained, and the DIP switches must be set for the bank as described in the manual. The Epoch Cloud app shows each battery and the whole bank on one dashboard.
LiFePO4 cells must not be charged below 0°C (32°F). When the battery is too cold to accept charge, the BMS uses incoming charge current to power the internal heating pads first, then allows normal charging once the cells reach a safe temperature. Expect a delay before the state of charge starts to rise. Discharge works down to -20°C (-4°F).
One battery supports about 4,096 W of continuous DC output at 51.2 V. Size inverters by their DC input current, which must stay within 80 A. If it can exceed that, add batteries in parallel. Planning runtimes at 80% of nominal energy (about 4,096 Wh) are roughly 41 hours at 100 W, 8.2 hours at 500 W, 4.1 hours at 1,000 W and 1.4 hours at 3,000 W.
| Model / SKU | C48100A-A (V2-T Elite Series) |
| Chemistry / configuration | LiFePO4, 16S1P |
| Nominal voltage | 51.2 V |
| Capacity / energy | 100 Ah / 5.12 kWh |
| Voltage range | 41.6–58.0 V |
| Continuous charge / discharge | 80 A / 80 A |
| Peak current | 250 A discharge (10 s), 90 A charge (5 s) |
| Integrated fuse | 250 A Eaton Class T, user-serviceable |
| Communication | Bluetooth via included gauge (Epoch Cloud app), Victron CAN-bus with DVCC |
| Charge temperature | 0°C to 55°C (32°F to 131°F); from -30°C (-22°F) ambient with self-heating |
| Discharge temperature | -20°C to 55°C (-4°F to 131°F) |
| Storage temperature | 0°C to 35°C (32°F to 95°F) up to 1 year |
| Series / parallel | Parallel only, up to 16 batteries; series and series-parallel not supported |
| Cycle life | 3,500+ cycles to 70% capacity |
| Enclosure | PC + ABS (UL94 V-0), IP67 |
| Dimensions | 20.86 × 8.65 × 12.06 in (529.8 × 219.8 × 306.3 mm) |
| Weight | 97 lb (44 kg) |
| Terminals | M8 bolts, torque 12 N·m (8.85 lb-ft) |
| Warranty | 11-year limited: 5 years free repair or replacement, then 40% off MSRP on a replacement battery through year 11 |
Program every charge source, Victron equipment included, to a lithium (LiFePO4) CC/CV profile: bulk/absorption 56.8 V, absorption time of at least 15 minutes per battery in the bank, float 54.0 V, equalization and temperature compensation disabled. Never charge above 58.0 V, and never use lead-acid equalization or desulfation modes. The combined charge current from all sources must stay within 80 A per battery. For alternator charging, use a DC-DC charger or an alternator regulator set up for lithium. Before first use, switch the battery on with the external power button and charge it fully.
This is a deep-cycle battery for house power and energy storage, not for engine starting, and it is designed for 48V (51.2 V nominal) systems only, so do not wire it in series. High-current DC systems should be installed by qualified personnel using correct conductors, disconnects, torque procedures and overcurrent protection. Install the battery upright and lift it with two people. Although the enclosure is IP67-rated, it is not designed for water jets, pressure washing or continuous submersion, so choose a location that stays dry in normal use, with all harness connectors fully seated. If you are replacing a Group 8D lead-acid battery, confirm tray fit, hold-down and lid clearance first. The optional Epoch V2 and V2-T 8D mounting bracket fastens to the threaded inserts on the case. When building banks, use matched batteries of the same age, capacity and state of charge.